大白菜平台送彩金

Industrial automation products

Servo Driver


  • Select view product parameters:
    Product feature

    ID680 Series driver  


    Product feature: 

    1. Equipped with LED operation panel to make debugging and maintenance more convenient and quick;
    2. More convenient matching of high and low level of I/O logic;

    3. Direct current reactance is built into specifications above 37KW to reduce the driving failure rate caused by grid distortion

    Product specifications
    Product Model Input Voltage/V Output Power/kw
    Rated Current/A
    1BX_ID680K1F3

    Three-phase

    390~480

    (±10%)

    11 25
    1BX_ID680K5F3
    15 32
    1BX_ID680K8F3 18.5 37
    1BX_ID680J2F3
    22 45
    1BX_ID680I0F3
    30 60
    1BX_ID680I7F3
    37 75
    1BX_ID680H5F3
    45 91
    1BX_ID680G5F3
    55 112
    1BX_ID680E5F3
    75 150
    1BX_ID680C0F3
    93 176


    • Technical Parameters
    Functional description Specification indexes 
    Power input Input voltage(V) AC  3PH  220V~480V
    Incoming current(A) Please refer to the rating
    Incoming frequency(Hz) 50Hz or 60Hz allowable frequency range is between 47~63Hz
    Power output Output voltageV 0~480V
    Output voltageA
    Please refer to the rating
    Outcoming frequencyKW
    Please refer to the rating
    Control performance
    Maximum output frequency
    300Hz
      Control method
    Close Vector loop
    • Motor type
    • Permanent-magnet synchronous motor
    • Control mode
    Injection molding machine mode, speed mode
    Pressure instruction type
    Analog instruction (DC0~10V)
    FDEM
    Analog instruction (DC0~10V)
    Peripheral interface
    Analog input
    3 ways,DC0~10V
    Analog output
    2 ways,DC0~10V
    Digital switching quantity input
    5 ways,Maximum frequency1kHz, Internal impedance:3.3kΩ
    Relay output
    3 ways(1st way open/close, 2nd way open)
    Contact capacity:3A/AC250V,1A/DC30V
    Defensive function
    19 kinds of fault protection functions: over current, over voltage, under voltage, over temperature, phase loss, overload and other protection functions
    Communicating function
    RS485,maximum 32 nodes; CAN communication, maximum 255 nodes
    Others
    • Installation
    Wall mounting and flange mounting are supported
    Operating ambient temperature
    -10~50℃, derating over 40
    Level of protection
    IP20
    • Cooling mode
    Forced cooling
    • Operation place

    • Altitude

    Temperature

    Vibration

    Storage temperature





  • Select view product parameters:
    Product feature

    DE688 Series driver  


    Product feature:

    1. Realize linkage, quick switching with follow, and coexistence of multiple control modes;

    2. Using NET/CAN and other communication methods to establish digital communication with the upper computer, the control is more accurate and the operation is more convenient.

    3, with short circuit, over current, over voltage, under voltage and other protection functions.

    4. Communicate with servo through NET, change driver parameters through HMI interface, or debug or repair through mobile phone APP software.


    Product specifications
    Product Model Input Voltage/V Output Power/kw
    Rated Current/A
    1BX_DE688K1F3

    Three-phase

    390~480

    (±10%)

    11 25
    1BX_DE688K5F3
    15 32
    1BX_DE688K8F3
    18.5 37
    1BX_DE688J2F3 22 45
    1BX_DE688I0F3
    30 60
    1BX_DE688I7F3
    37 75
    1BX_DE688H5F3
    45 91
    1BX_DE688G5F3
    55 112
    1BX_DE688E5F3
    75 150
    1BX_DE688C0F3
    90 176



    • Technical Parameters
    Functional description Specification indexes 
    Power input Input voltage(V) Three-phase 380 v; The voltage keeps fluctuating by plus ±10%
    Incoming current(A) Please refer to the rating
    Incoming frequency(Hz) 50Hz or 60Hz allowable frequency range ±5%
    Power output Output voltageV 0~380V
    Output voltageA
    Please refer to the table above
    Outcoming frequencyKW
    Please refer to the table above
    Control performance
    Maximum output frequency

      Control method
    Vector control
    • Motor type
    • Permanent-magnet synchronous motor
    • Control mode
    • Permanent-magnet synchronous motor
    Pressure instruction type
    Analog instruction (DC0~10V)
    FDEM
    Analog instruction (DC0~10V)
    Peripheral interface
    Analog input
    3 ways,DC0~10V
    Analog output
    2 ways,DC0~10V
    Digital switching quantity input
    6 ways
    Relay output
    6 ways
    Defensive function
    Short circuit protection, over current protection, over voltage protection, under voltage protection, over temperature protection, overload protection
    Communicating function
    CAN communication,E_NET
    Others
    • Installation
    Wall mounting and flange mounting are supported
    Operating ambient temperature
    -10~50℃, derating during 40℃~50℃
    Level of protection
    IP20
    • Cooling mode
    Forced cooling
    • Operation place
    Indoor, without direct sunlight, no dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt, etc
    • Altitude
    Lower than 1000 meters and lower than 1000 meters, the amount of reduction shall be 1% for each increase of 100 meters
    Temperature
    5%~95%RH, no condensation
    Vibration
    4.9m/s20.5G
    Storage temperature
    -40℃~+70




  • Select view product parameters:
    Product feature
    SIEMENS Series Drivers

    Siemens Drivers: 

    Include control unit CU305, the encoder conversion module SMC10 and the power module PM340;


    Control unit module CU305 CAN  Function: 
    Uniaxial servo controller with PM340 power module.

    Encoder conversion module set SMC10  Function: 
    When the motor does not have drive-cliq interface and USES a third-party servo motor, SMC10 module is required.


    Modular PM340 power module:
      
    Product feature:
    1. Control module and power module adopt split control, which is easier to maintainfloat:
    2, set vector control and servo control in one, to achieve a variety of control mode free switching
    3. CAN communication and upper computer are used to realize digital communication, and the control is more accurate
    4. BOP operation panel makes debugging and maintenance convenient and quick


    • Product specifications
    Product model
    • Output Power
    • /Kw
    Rated current/A
    6SL3210-1SE21-8UA0 7.5 18
    6SL3210-1SE22-5UA0 11 25
    6SL3210-1SE23-2UA0 15 32
    6SL3210-1SE23-8UA0 18.5 38
    6SL3210-1SE24-5UA0
    22 45
    6SL3210-1SE26-0UA0
    30 60
    6SL3210-1SE27-5UA0
    37 75
    6SL3210-1SE31-0UA0
    45 90
    6SL3210-1SE31-1UA0
    55 110
    6SL3210-1SE31-5UA0
    75 145
    6SL3210-1SE31-8UA0
    90

    178


    Technical Parameters

    Functional description
    • Specification index
    • Power input
    • (PM340)
    • Input voltage
    • (V)
    3 AC 380~480 V ±10%(-15% < 1 分钟)
    • Input current
    • (A)
    Please refer to the rating
    • Input frequency
    • (Hz)
    47~63 Hz
    • Power output
    • (PM340)
    • Output voltage
    • V
    0~480V
    • Output current
    • A
    Please refer to the rating
    • Output Power
    • KW
    Please refer to the rating
    • Control performance
    • CU305
      Control Method
      Open-loop vector control
    • Motor type
    Permanent magnet synchronous motor
    • Control mode
    Servo mode, vector mode, V/F control
    Flow instruction type
    Analog instruction (DC 0~10V或±10V)
    Peripheral interface
    CU305

    DRIVE-CLIQ interface


    PM-IF interface

    BOP20 rabbet

    CAN bus

    Channel encoder interface

    • Analog input channel


    Digital input

    Digital output
    RS232 interface

    MMC SD

    Temperature sensor interface

    SMC10
    DRIVE-CLiQ interface

    • Encoder Interface

    • Protection function
    Over current, over pressure, under pressure, over temperature, phase loss, overload, etc
    Communicating functionCU305
    CAN communication  RS232communication
    Others(PM340)
    Installation
    Wall mounting and flange mounting are supported
    Operating ambient temperature
    0~40?C,keep the capacity> 40~55?Csee the capacity curve
    Level of protection
    IP20
    Cooling mode

    Forced cooling is used in the power part

    Operation place
    Indoor, without direct sunlight, no dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt, etc
    Altitude

    Lower than 1000 meters and lower than 1000 meters, the amount of reduction shall be 1% for each increase of 100 meters

    Temperature 5%~95%RH, no condensation
    Vibration
    4.9m/s20.5G
    Storage temperature
    -40℃~+70






You must enter your password to download